FMX Errata

From C256 Foenix Wiki
Revision as of 07:11, 11 April 2020 by PJW (talk | contribs) (Errata: Known Issues with the Board or Firmware)
Jump to navigation Jump to search

Errata: Known Issues with the Board or Firmware

Errata 1---MIDI IN Port Pin Inversion (25/03/2020)
Pins 6 and 7 on the MIDI IN port of the RevC4A and RevC4B are reversed. Plugging a device into the MIDI IN port will result in a short from +5V to ground. The board can be fixed by cutting three traces (marked in blue in the diagram below), and then soldering two jumper wires (shown in orange). As an alternative if there is no desire to use MIDI IN, the pin connected to pad 7 in the diagram below could be lifted from the pad to prevent a short.

BoardErrata1.png

Errata 2---Floppy Mount Screw is Too Long (11/04/2020)
The screw close to the power switch, which is used to secure the floppy drive to the case is too long and interferes with the drive's internal tray that holds the disk in place. This prevents the disk from sitting correctly and interferes with the drive's ability to read the disk. The problem can be solved by loosening the scree 2 or 3 turns.

FMX Floppy Screw.jpg